We report here a new simple effective spectrophotometric simultaneous determination of Cobalt (II) and Iron (III) with Res-acetophenone guanylhydrazone [RAG]. A standard procedure of the absorption spectra of the reagent and the complex is recommended. The absorbance measurements of Co(II) are carried out at 415 nm [Molar extinction co-efficient is  0.4426 x 104 lit. mole cm-1] and at 520nm [Molar extinction co-efficient is  0.1230 x 104 lit. mole cm-1] while of Fe(III) at 415 nm [Molar extinction co-efficient is  0.1223 x 104 lit. mole cm-1] and at 520nm [Molar extinction co-efficient is  0.2016 x 104 lit. mole cm-1] at pH 7.6.  The method is applied for the determination of Cobalt and iron in steel alloy and synthetic mixtures.


Keywords

RAG, Cobalt(II), Iron(III) , Spectrophotometry


Cite This Article

Divate, V. A., Manoli, P. S., & Dhongade, S. R. (2014). A Spectrophotometric Simultaneous Determination of Cobalt (II) and Iron (III) With Res-Acetophenone Guanylhydrazone (RAG). International Journal for Pharmaceutical Research Scholars (IJPRS), 3(2), 582-585.