IJPRS

Home Article Development and Validation of UV Spectrophotometric Method of Cinitapride in Bulk and Tablet Formulations


Research Article

Development and Validation of UV Spectrophotometric Method of Cinitapride in Bulk and Tablet Formulations


Author(s)

Teja, C. R., Ramya, J. B., Sukanya, K., Sambasivinaik, N., Reddy, G. S. S.


Author's Affiliation


Abstract

The present research works discuss the development of a UV estimation method for Cinitapride. Simple, fast, accurate and cost efficient and reproducible. Spectrophotometric method has been developed for the estimation of Cinitapride at in bulk and tablet formulations. The wave length (λ max) selected for the Cinitapride at was 263 nm. The linearity for this drug at the selected wavelength is lies between 0.2 to1μg/ml. Beer’s law3,7 obeyed in this concentration range with correlation coefficient of 0.9999. The proposed method was successfully applied to the determination of cinitapride in pharmaceutical formulations without any interference from common excipients.


Keywords

Cinitapride, Absorbance, Validation, Detection Limit


Cite This Article

Teja, C. R., Ramya, J. B., Sukanya, K., Sambasivinaik, N., & Reddy, G. S. S. (2014). Development and Validation of UV Spectrophotometric Method of Cinitapride in Bulk and Tablet Formulations. International Journal for Pharmaceutical Research Scholars (IJPRS), 3(3), 118-121.