Research Article
Simultaneous Estimation of Metformin HCl and Gliclazide by Q-Analysis Method
Author(s)
Chopade, J. R., Deshpande, S. V., Shah, S.
Author's Affiliation
Abstract
Q- Analysis method for simultaneous estimation of Metformin HCl and Gliclazide in tablet dosage form have been developed. The method was simple, precise, accurate, reproducible and economical. Linearity was observed in the concentration range of 2-12 μg/ml for GLZ and 2-12 μg/ml for MET. The result of analysis have been validated as per ICH Guidelines.
Keywords
Gliclazide, Metformin hydrochloride, λmax, Q- Analysis method
Cite This Article
Chopade, J. R., Deshpande, S. V., Shah, S. (2013). Simultaneous Estimation of Metformin HCl and Gliclazide by Q- Analysis Method. International Journal for Pharmaceutical Research Scholars (IJPRS), 2(3), 66-73.